综合孔径微波辐射计成像观测能力

    Analysis of Synthetic Aperture Microwave Radiometer Imaging Observation Performance

    • 摘要: 对综合孔径微波辐射计成像观测原理进行了阐述,分析了综合孔径微波辐射计的灵敏度、积分时间、天线波束宽度、目标亮温、背景噪声温度、系统工作频率和目标等效截面等因素与系统作用距离的关系,对系统的目标观测能力进行仿真验证,探讨了阵列通道不一致等误差的补偿方法。研究成果将有助于综合孔径微波辐射计的实用化推进。

       

      Abstract: The fundamentals of imaging observation in synthetic aperture radiometer were present in this paper. The system parameters in synthetic aperture radiometer, such as brightness temperature sensitivity, integral time, antenna beam width, target brightness temperature, background noise temperature, operate frequency, target equivalent sectional area and so on were analyzed and the relationships between them and system operate distance were derived. The system observation performance was certificated through simulation and the methods for compensating the array errors such as inconsistent were discussed. The research results will be help to promote the engineering implementation of synthetic aperture radiometer.

       

    /

    返回文章