基于共铁塔的基站天线对在线监测设备电磁影响研究

    Electromagnetic Interference and Protection of Base Station Antenna on On-Line Monitoring Equipment on Shared Tower

    • 摘要: 随着共享铁塔建设的全面开展,基站天线对同塔布置的输电线路在线监测设备的电磁干扰问题开始凸显。结合在线监测设备的电磁兼容标准,揭示了基站天线对在线监测设备的电磁干扰机理。通过建立电大尺寸金属散射体无源干扰求解模型,采用物理光学-矩量法混合算法求解基站天线在铁塔表面产生的感应电流,获得了在线监测设备处的散射电场值。以山东35 kV 共享铁塔为算例,以天线工作频率、天线与在线监测设备之间的间距为变量,分析了铁塔塔头型式、天线功率、天线倾角等不同工况下的散射电场变化规律。结果表明,铁塔塔头型式对干扰影响较小,而天线功率和倾角对干扰影响较大。以此为计算依据,建议天线与在线监测设备之间的防护间距为18m。

       

      Abstract: With the development of the construction of shared tower, the problem of electromagnetic interference of base station antenna to transmission line on-line monitoring equipment emerges. Based on the EMC standard of on-line monitoring equipment, the mechanism of electromagnetic interference from base station antenna to on-line monitoring equipment is revealed. By establishing a passive interference solving model for electrically large metal scatterers and using PO-MOM hybrid algorithm to solve the induced current generated by the base station antenna on the surface of the tower, the scattering electric field values at the on-line monitoring equipment are obtained. Taking Shandong Province 35 kV shared tower as an example, the variation of scattering electric field under different working conditions, such as tower head type, antenna power and antenna inclination angle, is analyzed with antenna working frequency and the distance between antenna and on-line monitoring equipment as variables. The results show that the type of tower head has less influence on the interference, while the antenna power and inclination have greater influence on the interference. Based on this calculation, it is suggested that the protection distance between antenna and on-line monitoring equipment should be 18 m.

       

    /